Home > Products > High Voltage

    Type 1OKV XGN15-12 AC metal enclosed switchgear

    Brand: RENDA
    Model: XGN15-12
    Updated: 2015-10-28
    • Product description
    • Scope of application
    • Product features
    • Technical parameters

    1. Product overview

    XGN15-12 switchgear full name is XGN15-12 AC high voltage metal closed ring network switchgear, it is a kind of medium and high voltage ring network switchgear independently developed and produced by Renda according to market needs.

    This equipment complies with the International Electrotechnical Commission IEC298 "AC metal-enclosed switchgear and control equipment above 1KV and below 52KV", and China's GB3906 "3-35KV AC

    Metal-enclosed switchgear", DL404 and CQC's CCC national compulsory certification content, and has a complete anti-misoperation function.

    2. Product use

    XGN15-12 AC high voltage metal closed ring network switchgear is suitable for AC 50HZ, 10KV power network, the system is used to receive and distribute electric energy.

    3. Environmental conditions for product use

    (1) Ambient air temperature: upper limit +40 lower limit -35;

    (2) The altitude does not exceed 2500m (when it exceeds 2500m, it can be produced in consultation with the technical department of our company);

    (3) Relative humidity: the daily average is not more than 95%, and the monthly average is not more than 90%;

    (4) No regular severe vibration;

    (5) The surrounding air is not obviously polluted by corrosive gases or combustible gases, water vapor, etc.

    This equipment is used in power plants, substations, large buildings, high-rise buildings, airports, hospitals, theaters, stadiums, ports, underground equipment, industrial and mining enterprises, etc. As a 50HZ, AC 10KV power system, widely used in industrial and civil cable ring networks and power terminals, as the reception and distribution of electric energy

    Scalable for distribution automation. Compact structure, flexible assembly, reasonable distribution, neat arrangement, less floor space, firm structure, multiple interlocks, protection height, complete functions, safe and simple operation, good interchange performance, large short-term withstand current, unique compatible form, can install domestic and imported various series of circuit breakers.

    The ring network cabinet body is riveted and formed by 2mm thick aluminum-zinc plate, and there are two pressure relief holes in the back plate of the cabinet, one for the cable room and the other for the load switch/busbar room. This structure maximizes personal safety and the reliability of operating equipment. Compartments:

    1.     Busbar room: The busbar room is located on top of the cabinet and connects the adjacent switchgear.

    2.     The load switch is a stand-alone unit filled with SF6 gas inside.

    3. Electrical cables: About 75% of the space is used for cable connections, fuses, grounding switches and PT and CT installations.     

    4. Mechanism chamber and interlock

    : The chamber contains the interlock of the operating mechanism and the mechanism as well as position indication, auxiliary contact, trip coil, live display and interlock.     

    5. Low pressure box

    : The low pressure box is on the top of the cabinet and is optional.      The chamber is used to install special devices such as instrumentation / relays and motor units.

    6. Circuit breaker chamber: A circuit breaker (SF6 or vacuum) can be placed under the load switch.     

    7.     Pressure release:

    (1)    Pressure relief above: The above is used to release the gas pressure generated by arc accidents inside the bus bar and load switch room.

    (2)    The following pressure release: The following is used to release the gas pressure generated during an arc accident inside the cable chamber.

     

    Name

    Parameters

    Rated voltage (KV).

    10

    Rated lightning impulse withstand voltage

    Interphase, 75 kV to ground, 85 kV fracture

    Rated power frequency withstand voltage (1min).

    Interphase, ground 42KV, fracture 48KV

    Rated frequency (Hz).

    50/60

    Rated current (A) Main bus branch wire

    630 ,630

    Rated short-time withstand current (KA) main circuit ground loop

    20  ,20

    Rated short-circuit withstand current duration (S).

     3

    Rated peak withstand current (KA).

     50

    Transfer current (A).

     1700

    Degree of protection

     IP3X

    Load switch mechanical life (times).

     ≥5000

    Grounding switch mechanical life (times).

     ≥2000

    ? 1991-2024 Renda Group All Rights Reserved.  粵ICP備12015448號  
    99国产精品99久久久久久|A国产精品一区第二页|久久久久久精品成人自慰无码|亚洲国产激情av一区二区